Configure Localino Anchors
Configure Localino Anchors

Open a floor
Click on Configure floor [A]
▷ The sidebar changes.
Click on Start calibration [B]
▷ Note: If you see the message [G], anchors have already been configured for this floor.
In field [C1], specify how high (in meters) the floor of the selected floor is above the ground.
In field [C2], specify how high (in meters) the ceiling of the selected floor is above the ground.
Click on [C3]
▷ The options for the next step appear
In [D1], select at least 2 anchors
Optional: Activate [D2] to filter the list of anchors so that only anchors that are compatible with the previously made entries are displayed.
Click on [D3]
▷ The anchors [E] appear in the viewport. Individual anchors are displayed as red dots [E1]
Drag and drop the anchors into the desired position. The position of the anchors in Eliona must correspond as precisely as possible to the position of the hardware devices.
▷ You can only move/rotate/scale the anchors as a whole. You cannot edit individual anchors. The position of the respective anchor points to each other was previously determined in the Localino app.
▷ You can also rotate and scale the anchor arrangement. If necessary, use [E2] and [E3] to make fine adjustments.
Click on Save [F]
▷ The settings are applied
Adjust Localino Anchors afterward

You can adjust the configuration of the Localino anchors afterward.
Open a floor
Click on Configure floor [A]
▷ The message [G] appears in the sidebar. If this message is missing, no anchor calibration has been carried out yet.
Click on Reset [G1]
▷ The message [H] appears
Click on [H1]
▷ The position of the anchors is reset.
▷ All possibly connected Localino trackers are no longer displayed.
Proceed as described in the chapter ↗ Configure Localino Anchors.